Tag: cooling

  • HPH389: Air-to-air mini split heat pumps – with Es Tresidder

    HPH389: Air-to-air mini split heat pumps – with Es Tresidder

    Es Tresidder from Highland Passive explains what an air-to-air mini split heat pump is, why he believes it’s a good choice for heating a high performance home and the various pros and cons of going down this route. He also reflects on one of the toughest stages of his retrofit when they took the roof off the existing dwelling and then faced torrential rain.

    Interview with Es Tresidder

    Es Tresidder is a certified Passivhaus Designer with over a decade of experience in low energy buildings. His consultancy Highland Passive helps self-builders and retrofitters create better homes, that are healthy, comfortable and energy efficient. He’s also been working on various projects for John Gilbert Architects over the years, and he’s a regular at House Planning Help as part of our ‘ask the expert‘ team in The Hub.

    Es has been on the podcast before, explaining how he upskilled in DIY during his retrofit project. In this session he’s reflecting on the whole process, including a key challenge he faced with water damage, and he’s going to go into detail about how he heats his home with an air-to-air mini split heat pump.

    Es is a regular in The Hub where he helps answer questions on building physics and retrofit

    Vehicle-to-load allows you to use an electric car’s battery to power external devices

    This podcast was recorded during a power cut and was only possible because Es has an electric car capable of vehicle-to-load, which means that you can plug an adapter in to where you normally plug it in to charge, and then plug a three pin, normal domestic plug into that, and run that into your house. He explains that you can’t power your whole house, but you can take three kilowatts from it, which he was using with three or four extension cables strewn around the house, to power the fridge freezer, the dishwasher, the Wi-Fi, to charge computers and even to make a loaf of bread overnight!

    “…logically, you know that electricity is very, very useful in life, but life just becomes much harder as soon as you don’t have electricity.”

    When Es put the services into the house, he created a service void, which is effectively a pipe that goes through the external wall with an airtight membrane on one side and a windtight membrane on the other. This means he can add new cables into the house and make them airtight easily. He did this when adding solar PV to the roof and now he’s done it again, putting in a permanent extension cable that can connect to the car, ready for the next power cut.

    Home battery systems with ‘island mode’ help you operate independently from the grid during a power cut

    Es explains that domestic inverters shut down when the grid fails, preventing the house from drawing power from solar PV panels during an outage. However, if you have a home battery system you can pay extra so that you can island from the electricity grid, which would happen automatically during a power cut. However, domestic batteries are only around seven to 12 kilowatt hours, so if it was January or February, with little solar power generation, you’d quite quickly go through your battery’s power, even in a Passivhaus. A car battery is much bigger, around 77 kilowatt hours, which would last several days during mid-winter, running heating as well as everything else. Another advantage is that if the power cut lasted much longer, he could just drive into town to a public rapid charger and top the car back up.

    Getting the MVHR back on was a priority because it immediately improves the health and comfort of the home

    Es says the MVHR has a really small energy requirement and is beneficial in lots of ways, so it was the first thing they plugged in. Until that point they had been keeping windows open for ventilation and, with an outdoor temperature of 12-13 degrees, the temperature inside had dropped down to around 17 degrees.

    The existing dwelling before any alterations

    The completed project

    Photography by Alex Trowski, commissioned for a case study in Passive House Plus Issue 50

    The retrofit, extension and remodel has made the whole house work better as a home

    Es’s house was a 1975 timber-frame build of one and a half storeys, where the first floor rooms felt quite pokey. So the strategy was to take the whole first floor off and rebuild it as a one and three-quarter storey house. This may not sound like a big increase, but Es says it gave a lot of extra floor space on the top floor, with enough for an extra bedroom, and an increase in size for the other bedrooms. The floor plan just worked much better.

    The upper floor is a new build Passivhaus, with an I joist timber frame sitting on top of the existing structure, which was quite complicated to do. Downstairs is a retrofit of a 100mm timber frame house, where the plasterboard was taken off and insulation put between the studs. He then added another 40 mm of wood fibre insulation board, an airtightness membrane, and then outside of that is white rendered blockwork. There’s a cavity between the two. As a Passivhaus Designer, Es did all the energy side of things and a lot of the retrofit work himself. The new build was carried out by a local contractor.

    The project involved removing the pitched roof and extending upwards

    Keeping a flat roof dry is incredibly difficult

    This project required the first floor and roof to be removed, which is slightly unusual. When they were looking at the options, one way to keep everything dry was to put up a massive tent over the whole structure, but this would set them back £30,000. The builders, however, were confident that they could keep the water out because they had done this many times before. There was also the fact they would be doing this in May which is statistically the driest time of the year in Fort William. Unfortunately the weather did not play ball and it was an unusually wet month. Es also points out that although the builders take off lots of roofs they probably don’t remove the whole structure leaving effectively a flat roof to keep dry.

    So it just became impossible to protect the structure from the torrential rain. Es had already insulated the ground floor and achieved good airtightness but the rain soaked the floorboards and insulation, forcing him to strip them out and replace everything.

    “You don’t want to install any insulation until the building is watertight.”

    A lot of insulation got waterlogged and had to be replaced

    Sequencing the work differently would have avoided damaging the insulation

    If doing the project again Es would not necessarily pay for the giant waterproof tent but he would sequence things differently. The work downstairs had been done first to ensure structural stability for the new first floor and roof. However once rain had compromised the work, they had to go ahead without the extra racking boards on the walls anyway or the racking strength from the floor. He would therefore consult a structural engineer to look at any structural elements that could be done without involving the insulation.

    The unit inside the house

    An air‑to‑air mini split heat pump is a cost effective way to heat a low energy home

    For Es, a heat pump is an obvious choice over direct electric resistance heating. However, instead of a conventional air‑to‑water heat pump system, Es chose an air‑to‑air mini‑split system. He explains that this is like an air conditioner, which usually pumps heat from inside to outside a building, but can also be used to pump heat from outside to inside a building. They have a similar efficiency to an air-to-water heat pump, but are much cheaper to install, because there’s no need for radiators or a wet system. The mini split has an outdoor unit and an indoor unit, with refrigerant lines between the two. The unit and installation cost was around £1,500 compared to £12 000 for the air‑to‑water system. Es is clear that this system is great for a Passivhaus but wouldn’t work for a normal new build house as it only delivers heat into one room and relies on heat spreading to other rooms.

    The unit outside the house

    Reversible operation provides useful cooling in heatwaves

    Mini‑splits can run in reverse to deliver modest cooling, which has proved handy for Es during a heatwave which coincided with the midge season (when they don’t really want to open any windows) and a large group of friends staying over and thus raising the indoor temperature.

    Sizing the mini split above peak load ensures comfort in cold snaps

    The house’s peak heating demand is around 1.3 kW and by selecting a 2.7 kW mini‑split Es has provided a comfortable margin, which allows the system to cope with occasional freezing cold days without needing supplementary electric heaters. In cold weather he will run the system overnight when electricity is cheaper, so increasing the temperature in the main parts of the house, whilst the bedrooms stay cooler. Once the doors are open the heat can spread through the house. He admits that having his office in his bedroom means occasionally it can be cooler than he would like and so a small electric heater would probably be a good addition.

    Photography by Alex Trowski, commissioned for a case study in Passive House Plus Issue 50

    Locate an air-to-air mini split system in a large open area

    Es explains that the mini split system needs to be in a space big enough to deliver a lot of heat into it, before warming that space to above the set point temperature. A small room would reach that temperature quickly then the system would shut off and so not provide enough heat for the rest of the house. The indoor fan also produces a low hum comparable to a refrigerator, louder than the house’s MVHR, so you need to place it where the noise won’t matter too much. Es stresses that whilst the MVHR supplies fresh air, and recovers heat it only moves a small amount of warm air between rooms. Keeping interior doors open lets the warm air from the mini‑split circulate more effectively.

    Grants favour air-to-water systems, but air-to-air systems may still be cheaper

    Even though Scottish renewable‑heat grants are available for air‑to‑water heat pumps and not for air‑to‑air units, Es feels the air‑to‑air solution may still be cheaper. The grant system also involves a lot of paperwork and restricts you to using MCS certified contractors, who are not necessarily the best. For a Passivhaus going down the air-to-air route also means you keep things simple.

    A standalone hot water pump works alongside the air-to-air system

    Whilst air-to-water heat pumps can also be used to supply hot water, an air-to-air mini split system is just warming the air in the house. So Es has installed a heat pump water heater, which is a 200 litre insulated hot water tank with a small heat pump on top. They are normally ducted to the outside to bring fresh air into the heat pump, the heat pump takes some heat out of that outdoor air, and then it ducts the exhaust air back out. Es has set his up to take heat from the house, which gives some free cooling in the summer and a much faster reheat time in the winter. It’s also easier from an airtightness point of view as it is not ducted to the outside at all. In the winter, the water heat pump is slightly cooling the house, so the mini split has to work a bit harder, but overall, it is still very efficient.  

    Living in the house has been amazing

    The house before Es started had quite serious mould and damp problems. They were always a bit chilly in winter and couldn’t dry things because there was no reliable ventilation, and the house wasn’t warm enough. Now things are completely different.

    “It’s hard to remember how it was before, because it’s just so nice now.”

    The house is warm and comfortable all the time in every room. Es believes it’s almost more impressive in hot weather than it is in cold weather, when you expect it to be warm. Es says that the first summer they moved in, they had two separate weeks of more than 28 degrees as peak temperatures in the afternoon. And in those conditions, the house was at 23 degrees, and it felt like walking into an air-conditioned space. It has really improved the quality of life. The air is clean and just walking outside the house, Es immediately notices if the neighbours oil boiler is running or there’s a coal or wood fire on locally.  He thinks his sense of smell has improved, because he’s used to clean air and the house smells fresh all the time. The best thing isn’t the bills, but it’s the most quantifiable thing. He’s reduced his heating bill by at least 80% while also massively increasing the average temperature of the house.

    “After one full year of monitoring we have spent £175 on heating and hot water for a family of five, which is remarkable.”

    Find out more

    Highland Passive

    Heat Geek

    OpenEnergyMonitor

    Transcript

    Download a transcript of this episode.

    Please connect with us

    Subscribe, rate and review us on Apple Podcasts

    Follow Ben Adam-Smith on LinkedIn

    Follow Ben Adam-Smith on Bluesky

  • HPH346: Passivhaus homes where cooling is a key consideration – with Andy Marlow

    HPH346: Passivhaus homes where cooling is a key consideration – with Andy Marlow

    Andy Marlow from Envirotecture explains why Passivhaus homes are a good fit for most climates in Australia, how they approach these projects and what is needed beyond shading to keep the homes comfortable when the outdoor temperatures soar.

    Interview with Andy Marlow

    Ben Adam-Smith has started this year with a visit to see his brother in Australia and, naturally, it was a great opportunity to record some more podcasts.

    On his previous visit he caught up with sustainability expert Michael Mobbs and Clare Parry who was then Director of the Australian Passivhaus Association.

    On this trip Ben has three more interviews. In this episode we meet Andy Marlow, Director at Envirotecture, who designed Sydney’s first Passivhaus in Thornleigh in 2018. He has since been involved in numerous new build and EnerPHit projects, all of which require an element of cooling. In today’s chat, Andy gives us an insight into Australia’s current housing stock, explains why Passivhaus is a logical choice for creating healthy and comfortable homes, and he outlines the main ways to incorporate cooling into a Passivhaus build.

    The ‘look’ of a home tells you nothing about its quality

    Andy describes the majority of Australia’s houses as “fancy looking sheds”.

    With a warmer climate in many parts of the country there is a culture of opening all the doors and windows, and creating a wonderful indoor/outdoor lifestyle! In reality, temperatures are frequently unpleasant as is the humidity and, due to the poor standard of construction, there is no refuge indoors.

    In fact most houses in Australia will rely on mechanical cooling via ducted air conditioning units. Because the houses are poorly insulated, the coolth generated often escapes the house, meaning that these systems operate incredibly inefficiently.

    Andy also points out that Australia not only builds the largest houses in the world with the national average being 244 square metres (3x the UK average) but also the cheapest per square metre. This poses quite a challenge for the uptake of Passivhaus because it is going to be slightly more expensive than a traditional build which may in turn lead you to reduce the floor area (which many Australians may not be keen to do).

    A skills shortage is impacting the quality of homes

    Australia is also facing a skills shortage in the construction industry because of a nationwide shift towards higher education. Whilst this has many other benefits, the impacts on construction means it can be harder to find contractors and with less competition, they are able to charge a higher price for a lower standard of work. This is not the case for everyone or everywhere in Australia, but Andy does think this has had a significant impact on the quality of the current housing stock.

    Huff n’ Puffhaus – Strawbale construction method

    In some climates cooling will be required

    Although the Passivhaus methodology is the same no matter where you are in the world, in Sydney’s climate the challenge is more about cooling than heating.

    Good design can reduce the risk of overheating

    Andy explains that carefully placed and smaller windows can have a big impact in reducing the need for cooling. Likewise shading from an eaves overhang or external blinds will help. Natural cooling and cross ventilation by opening tilt turn windows can also work if temperatures drop overnight. However, it is not uncommon for Australia to reach 40 degrees, so there is often also a need for mechanical cooling systems.

    “The biggest practical issue that we face as architects and designers in Australia is the expectation around the size of windows and doors. A lot of it comes back to that indoor/outdoor lifestyle and people’s desires, expectations, and beliefs around that. Basically, you hit a point where it doesn’t matter how good the glass is or how good your eaves are, you start needing to use external blinds or things that are directly adjacent to the window to keep the sun off them. You also just hit a point where regardless, there’s just too much glass.”

    When looking at cooling, energy efficiency is key

    Because of the efficiency of Passivhaus homes, they can work very well in partnership with air conditioning systems. In much of the current housing stock, air conditioning units supply the cool air to each room of the house through a duct system. Due to the fact that these houses are poorly insulated, a large proportion of this cool air is lost though the walls, ceiling, etc. making the whole system inefficient. The high performance fabric of a Passivhaus means very little of this cool air will be lost and as a result, the cold air can be delivered in one or two areas and spread throughout the whole house naturally or through the ventilation system.

    “Every one of the certified Passivhauses that we’ve done have mechanical cooling. It’s very, very common here. 86% of new houses in Australia have mechanical cooling.”

    On top of this, the MVHR removes the heat from the fresh, incoming air but retains the coolth from inside the house. This massively reduces the amount of energy needed to cool a house. With higher temperatures every year as a result of climate change, Passivhaus is an excellent option to reduce the energy demand and keep homes cool.

    Design drawings and ventilation plans for Thornleigh Passivhaus

    A Passivhaus will be comfortable in all climates

    Andy explains that they always design their Passivhaus homes to stay between 20-25 degree celsius internally, but some clients may ease off on the cooling, save a bit of money and just live in a slightly warmer house. It’s down to personal preference.

    There is a big range of outdoor temperatures in Australia (over the course of the year) and it is common for most parts to reach 40 degrees during the day at some point, possibly reducing to 5 degrees at night during the coldest times. However, there are also areas in the mountains that can get down to -10 degrees so each project must take into account the local climate data.

    Health and comfort benefits are key drivers

    Most of Andy’s clients have been people who have lived abroad and experienced the standard of housing in other countries. In returning to Australia, they realise how low the standard is in the current housing stock and set out on new build or retrofit projects to try and change this.

    “It’s the hardest part of everything we do without a shadow of a doubt, we joke that 5% of our job is design and the 95% is making stuff happen. It’s mostly successfully sold when people comprehend the benefits and the benefits have nothing to do with the money. It’s mostly around the health and comfort. That’s partly because of the quality of everything else that exists: if I don’t do this, what will I end up with? And the answer to that is normally too hot, too cold, too mouldy. If you don’t want that, you end up in this long discussion, which concludes you need to build something that looks remarkably like a Passivhaus.”

    Sydney’s first Passivhaus: Thornleigh

    Andy worked to deliver Sydney’s first Passivhaus in 2018:

    “It’s in the middle of suburban Sydney. It’s got a massive five metre wide north facing window in it. Interestingly, it’s got no eaves on it, which was a deliberate choice, but it’s got external blinds on it. We did it for a whole host of reasons, to get as much solar gain as we could in winter and the blinds give us real control during the summer. They come at a price obviously, but everything in building comes at a price. However, they also require the occupants to use them, so there’s no point having a blind if someone doesn’t press the button for it to come down. These clients are incredibly active in the management of the house, so it works like a charm.”

    Renewables are common, energy efficiency is not

    A large proportion of Australia’s houses are fitted with solar PVs and the majority of new builds have them as a requirement, which is economical for a country with so much sun. However, with an inefficient housing stock they are consuming a lot of energy every day. The challenge is therefore not solely focused on how energy is generated but also how much is consumed.

    “A lot of big inefficient houses with big air conditioners, while they might make a lot of electricity at various points, in the middle of big electricity spikes, they’re going to struggle. But also when the system crashes, then they’re completely stuffed.”

    There has been a recent shift towards batteries as people are deciding to prioritise personal resilience, but also because the feed-in tariffs supplied by energy companies have dropped quite significantly and it no longer feels worth it. If Passivhaus became mainstream in Australia, the combination of energy-efficient homes and personal renewable resilience would put them in an excellent position to face incoming climate challenges.

    The conversation around embodied carbon

    Andy highlights that in Australia, the national conversation on embodied carbon is behind the curve. There is a reliance on concrete for building foundations and the houses are often large. However, the default approach to building is with timber frame meaning they don’t face the same challenge as the UK in needing to transition away from brick and block construction.

    Huff n’ Puffhaus: Straw bale construction process

    The Australian construction industry relies on imported materials

    Australia imports a lot of supplies for low energy projects and as a result 80% of a house might need to be sourced elsewhere. Materials such as glass, insulation, membranes, mechanical ventilation systems/ducting and any new technological developments are all brought into the country and are therefore expensive items. Australia does have a large timber industry so wood is more easily accessible but there is still a reliance on imports to meet demand.

    Some materials that are commonly used in the UK such as I-joists are not as needed in Australia because their buildings don’t require as much insulation. Andy notes that 140mm stud walls often offer a sufficient wall thickness in order to meet Passivhaus standard. Wood fibre board would be a great material for Australian Passivhauses to eliminate thermal bridges but it is bulky and as a result expensive to import.

    Design approaches: new build and retrofit

    Andy explains the process he would take when beginning a Passivhaus project:

    1. Design brief – Setting the parameters for what we are trying to achieve. Why are you doing this? What do you want? And for retrofit, what’s wrong with the house right now?
    2. Work out the practical details – What is the building going to look like? How is it going to get built? Is it a professional builder or a self build project?
    3. Design development phase – Get as many details as possible in place as early as possible because once it has been taken to planning, it can be hard to change.
    4. Post planning – Focus on the detailing, construction documentation and refining interiors.

    “We spend a lot of time getting our interiors to absolutely sing because that’s the stuff you end up looking at every day.”

    New builds go pretty smoothly. The most common time for issues to arise is during groundworks when something is uncovered that no one knew about, but most of the time the process is smooth. In the case of retrofit projects, Andy explains that he prefers to wait until the building has been stripped back to work out the specifics of the technical design as you never know what you will find hidden behind the walls. There have been many occasions where this stage has uncovered issues that show their original plan wouldn’t work and a different approach was needed. Andy recommends creating an overarching design which includes the materials you plan to use before you begin to dismantle the existing structure so you have an idea, but to avoid trying to plan out specific construction methods or details before this step, as you will likely end up having to repeat the process.

    Envirotecture currently have 2 EnerPHit projects certified and many more in the works.

    Thornleigh Passivhaus: Internal water tank feature

    Recommendation is still the best way to find good builders

    Envirotecture has developed relationships with a number of builders over the years and so that will tend to be the first avenue they explore. However if you are going into a new area, Andy follows these three steps:

    1. Seek recommendations from people you know and trust.
    2. Use the list of certified tradespeople on the Australian Passivhaus Association database.
    3. If the other two steps have been fruitless, ring people in the area and ask a “dumb question” that will highlight how much they really know about Passivhaus – this will help you find the people who buy into the approach and commit to the attention to detail necessary.

    The team you assemble doesn’t necessarily need Passivhaus experience, but they do need to be enthusiastic and have an interest in learning.

    Knowledge is key

    Andy offered some overarching advice to anyone who might want to take on a Passivhaus project:

    “Knowing as much as you can before you start is the key. Ask lots of questions of people who should know decent answers and if you don’t understand the answer, ask the same person again. If it still doesn’t make sense, ask someone else. The more competent professionals you surround yourself with, the easier that’s going to be. It is significantly cheaper, and easier and less stressful to learn from other people’s mistakes, I would recommend leveraging them as much as possible. You will make some of your own, everyone does, realise them as quickly as you can, learn, move on, try not to do it twice!”

    Find out more

    Visit the website of Envirotecture and follow along on their blog for more updates

    Follow Envirotecture on Instagram and Linkdin

    Special thanks to Ruth Butler for connecting us with Andy – Listen to Ruth’s episode here: HPH177

    Transcript

    Please connect with us

    Subscribe, rate and review us on Apple Podcasts

    Like our Facebook page

    Follow us on X